Product Details:
Contact Now
Chat Now
|
| Power Rating: | 50W | Resistance Tolerance: | 5% |
|---|---|---|---|
| Type: | Fuse Resistor | Shape: | Tubular |
| Transport Package: | Carton | Quantity: | Single Connection |
| Resistance Change Scale: | Linear Scale | Name: | Cement Fixed Resistors |
| Highlight: | Tubular Shape Cement Fixed Resistors,Cement Fixed Resistors 50W,Cement Fixed Resistors High Insulation Strength |
||
Hight Quality Cement Fixed Resistors 50W
Introduction
| 1. Low Noise And Heat Dissipation: Features low noise operation and excellent heat dissipation for stable performance | ||
| 2. Strong Overload Capacity: Capable of handling short-term overloads with minimal resistance variation | ||
| 3. High Insulation Strength: Provides reliable insulation strength when mounted on circuit boards | ||
| 4. Linear Temperature Coefficient: Exhibits linear change in resistance-temperature coefficient for precision | ||
| 5. Low Temperature Coefficient: Ensures stable resistance values across temperature changes | ||
![]()
| Watts | L±1 | W±1 | H±1 | I±2 | φd±0.05 |
| 2W | 18 | 6.5 | 6.5 | 18 | 0.6 |
| 3W | 22 | 8 | 8 | 20 | 0.6 |
| 5W | 22 | 10 | 10 | 22 | 0.6 |
| 7W | 35 | 10 | 10 | 22 | 0.7 |
| 10W | 48 | 10 | 10 | 25 | 0.7 |
| 15W | 48 | 12 | 12 | 25 | 0.78 |
| 20W | 64 | 13 | 13 | 28 | 0.78 |
| 30W | 75 | 19 | 19 | 30 | 0.78 |
| 50W | 90 | 19 | 19 | 30 | 0.78 |
| 100W | 135 | 22 | 22 | 30 | 0.78 |
| Feature project | Specification value | Test method |
| Temperature coefficient |
Metal oxide film:±350ppm/℃ |
Test temperature:Romm temperature +100℃ |
| Short term over load | ±(2%+0.05Ω)Max | Rate power×10 times,5 seconds |
| Insulation impedance | 1000MΩ MIN | Place in V-shaped groove method,apply DC voltage for 60 seconds |
| Withstanding voltage | No burning damage or insulation damage | Apply AC voltage to each specification for 1 minute |
| Load life | ±(5%+0.05Ω) MAX | Continuous for 1000 hours in an environment with a temperature fo 70℃ and reted voltage of 1.5 hours (ON) and 0.5 hours (OFF) |
| Moisture resistance load | ±(5%+0.05Ω) MAX | Rated voltage for 1.5 hours (ON) and 0.5 hours (OFF) in an environment with a temperature of 40℃ and a humidity of 95% RH for 1000 hours |
Contact Person: Mr. Jim
Tel: 15361036926